**************************************** UUT Report Serial Number: 200819001c Date: 10/4/2019 Time: 5:09:55 PM Operator: tester UUT Result: Passed **************************************** Fixture ID: Passed Fixture ID OK Fixture Down Detect: Passed Fixture Down Test Power Supplies: Passed Test Power: Passed Measurement: 4.99881 Limits: Low: 4.75 High: 5.25 Comparison Type: GELE (>= <=) Test Power: Passed Measurement: 12.0063 Limits: Low: 11.7 High: 12.3 Comparison Type: GELE (>= <=) Test Power: Passed Measurement: 12.0031 Limits: Low: 11.7 High: 12.3 Comparison Type: GELE (>= <=) Test Display Volts: Passed Measure Volts: Passed Measurement: 12.005406 Limits: Low: 11.5 High: 12.5 Comparison Type: GELE (>= <=) Measure Volts: Passed Measurement: 4.9520506 Limits: Low: 4.75 High: 5.25 Comparison Type: GELE (>= <=) Test Serial Communications: Passed Test Instrument Identification String: Passed String: Temperature Control Module Limits: String: Temperature Control Module Comparison Type: Ignore Case Power On Initialization Sequence Complete Clear Serial Recieve Buffer: Passed Test Command Monitor Response: Passed Set TCM Defaults: Passed lreset Set TCM Remote ON: Passed remote 1 Clear Serial Recieve Buffer: Passed Test Heaters Exist: Passed Clear Serial Recieve Buffer: Passed Heater 1 Present ?: Passed Heater 2 Present ?: Passed Heater 3 Present ?: Passed Test Temperature Accuracy: Passed Clear Serial Recieve Buffer: Passed Channel 1 Accuracy: Passed Measurement: 102.10186 Units: degrees Celsius Limits: Low: 101 High: 103 Comparison Type: GELE (>= <=) Channel 2 Accuracy: Passed Measurement: 101.945908 Units: degrees Celsius Limits: Low: 101 High: 103 Comparison Type: GELE (>= <=) Channel 3 Accuracy: Passed Measurement: 101.883324 Units: degrees Celsius Limits: Low: 101 High: 103 Comparison Type: GELE (>= <=) Test Temperature Variation: Passed Temp Variation Test: Passed Measurement: 0.19 Units: °C Limits: Low: 0.50 Comparison Type: LE (<=) Test Heater Output: Passed Set CHM 1 for 0°C: Passed setchantemp 0 0 Set CHM 2 for 0°C: Passed setchantemp 1 0 Set CHM 3 for 0°C: Passed setchantemp 2 0 Show Heater CHM 1: Passed Set CHM 1 for 125°C: Passed setchantemp 0 125 Verify Heater 1 On: Passed Number of Loops: 4 Number of Passes: 2 Number of Failures: 2 Final Loop Index: 4 Heater On Verify Heater 1 On (Loop Index: 0): Failed Heater Off Verify Heater 1 On (Loop Index: 1): Failed Heater Off Verify Heater 1 On (Loop Index: 2): Passed Heater On Verify Heater 1 On (Loop Index: 3): Passed Heater On Show Heater CHM 2: Passed Set CHM 2 for 125°C: Passed setchantemp 1 125 Verify Heater 2 On: Passed Number of Loops: 2 Number of Passes: 2 Number of Failures: 0 Final Loop Index: 2 Heater On Verify Heater 2 On (Loop Index: 0): Passed Heater On Verify Heater 2 On (Loop Index: 1): Passed Heater On Show Heater CHM 3: Passed Set CHM 3 for 125°C: Passed setchantemp 2 125 Verify Heater 3 On: Passed Number of Loops: 2 Number of Passes: 2 Number of Failures: 0 Final Loop Index: 2 Heater On Verify Heater 3 On (Loop Index: 0): Passed Heater On Verify Heater 3 On (Loop Index: 1): Passed Heater On Set CHM 1 for 0°C: Passed setchantemp 0 0 Set CHM 2 for 0°C: Passed setchantemp 1 0 Set CHM 3 for 0°C: Passed setchantemp 2 0 Test IEEE Communications: Passed IEEE 488 Test: Passed Number of Loops: 1 Number of Passes: 1 Number of Failures: 0 Final Loop Index: 1 IEEE 488 Test (Loop Index: 0): Passed End UUT Report