**************************************** UUT Report Serial Number: 251118060G Date: 11/7/2019 Time: 8:21:55 AM Operator: tester UUT Result: Failed **************************************** Fixture ID: Passed Fixture ID OK Fixture Down Detect: Passed Fixture Down Test Power Supplies: Passed Test Power: Passed Measurement: 5.00768 Limits: Low: 4.75 High: 5.25 Comparison Type: GELE (>= <=) Test Power: Passed Measurement: 12.0053 Limits: Low: 11.7 High: 12.3 Comparison Type: GELE (>= <=) Test Power: Passed Measurement: 12.0027 Limits: Low: 11.7 High: 12.3 Comparison Type: GELE (>= <=) Test Display Volts: Passed Measure Volts: Passed Measurement: 12.003121 Limits: Low: 11.5 High: 12.5 Comparison Type: GELE (>= <=) Measure Volts: Passed Measurement: 4.944375 Limits: Low: 4.75 High: 5.25 Comparison Type: GELE (>= <=) Test Serial Communications: Failed Test Instrument Identification String: Passed String: Temperature Control Module Limits: String: Temperature Control Module Comparison Type: Ignore Case Power On Initialization Sequence Complete Clear Serial Recieve Buffer: Passed Test Command Monitor Response: Failed Receive String Not Complete Clear Serial Recieve Buffer: Passed End UUT Report