<?xml version="1.0" encoding="UTF-8"?>
<ICSResources language="English" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="Q:\CoInstrument\XML\ICSResources-r100.xsd">
  <TypeCollection name="Dictionary">
    <Type name="gBoolean">
      <Enum value="No" id="BooleanNo_0A"/>
      <Enum value="Yes" id="BooleanYes_1A"/>
      <Enum value="Off" id="BooleanOff_0B"/>
      <Enum value="On" id="BooleanOn_1B"/>
      <Enum value="false" id="BooleanFalse_0C"/>
      <Enum value="true" id="BooleanTrue_1C"/>
    </Type>
    <Type name="gEditorStrings">
      <Enum value="About A-10 UV Detector..." id="EditAbout"/>
      <Enum value="UV Detector Editor Control" id="EditMgrTypeName"/>
      <Enum value="UV Detector" id="EditorTitle"/>
      <Enum value="Modify %s Instrument Method" id="EditorDialogTitle"/>
      <Enum value="Absorbance Minimum:" id="RatioMinimumLabel"/>
    </Type>
  </TypeCollection>
  <TypeCollection name="Config">
    <Type name="xsd:string">
      <Prompt value="Firmware Version" id="FirmwareVersion"/>
      <Prompt value="Software Version" id="IcsVersion"/>
      <Prompt value="Checksum" id="Checksum"/>
      <Prompt value="Serial Number" id="SerialNumber"/>
      <Prompt value="Lamp Serial Number" id="LampSerialNumber"/>
    </Type>
    <Type name="xsd:boolean">
      <Prompt value="Shutter Idle Mode enabled" id="ShutterIdleEnabled"/>
      <Prompt value="Supports Reduced I/O" id="SupportsReducedIO"/>
      <Prompt value="Supports Temperature Control" id="SupportsTempControl"/>
      <Prompt value="Supports Lamp Memory Device" id="SupportsLampMemDevice"/>
      <Prompt value="Supports Flow Cell Memory Device" id="SupportsFlowCellMemDevice"/>
      <Prompt value="Supports Cooler Hardware" id="SupportsCoolerHardware"/>
    </Type>
  </TypeCollection>
  <TypeCollection name="Report">
    <Type name="tMessageList" prompt="Messages"/>
    <Type name="tLampHours" prompt="Lamp Life"/>
    <Type name="tLampChanged" prompt="Lamp On/Off Event"/>
    <Type name="tFlowCellVariety" prompt="Flow Cell Type">
      <Enum value="Analytical LG" id="FlowCellVariety_1"/>
      <Enum value="High Sensitivity LG" id="FlowCellVariety_2"/>
      <Enum value="Analytical Fused Silica LG" id="FlowCellVariety_3"/>
      <Enum value="High Sensitivity Fused Silica LG" id="FlowCellVariety_4"/>
      <Enum value="Stainless Steel" id="FlowCellVariety_5"/>
      <Enum value="Titanium" id="FlowCellVariety_6"/>
      <Enum value="Nano-Scale Capillary" id="FlowCellVariety_7"/>
      <Enum value="Low Dispersion Microbore LG" id="FlowCellVariety_8"/>
      <Enum value="Micro-Scale Capillary LG" id="FlowCellVariety_9"/>
      <Enum value="Low Dispersion Analytical LG" id="FlowCellVariety_10"/>
      <Enum value="Stainless Steel" id="FlowCellVariety_11"/>
    </Type>
    <Type name="tFlowCellPathLength" prompt="Flow Cell Path Length" units="mm"/>
    <Type name="tFlowCellVolume" prompt="Flow Cell Volume" units="microliters"/>
    <Type name="tTempControlSetting" prompt="Optics Temperature Stabilzation Setting">
      <Enum value="Maximum Cooling" id="TempControlSetting_0"/>
      <Enum value="Normal Temperature" id="TempControlSetting_1"/>
      <Enum value="Elevated Temperature" id="TempControlSetting_2"/>
      <Enum value="unknown" id="TempControlSetting_99"/>
    </Type>
    <Type name="tFlowCellSerNum" prompt="Flow Cell Serial Number"/>
    <Type name="tFlowCellPartNum" prompt="Flow Cell Part Number"/>
  </TypeCollection>
  <TypeCollection name="Method">
    <Type name="tRunTime" prompt="Run Time" units="min"/>
    <Type name="tWavelengthMode" prompt="Wavelength Mode" units="">
      <Enum value="None" id="WavelengthMode_0"/>
      <Enum value="Single Wavelength" id="WavelengthMode_1"/>
      <Enum value="Dual Wavelength" id="WavelengthMode_2"/>
    </Type>
    <Type name="tLamp" prompt="Lamp On"/>
    <!-- Begin Channel -->
    <Type name="tChannel">
      <Prompt value="Channel A" id="ChannelA"/>
      <Prompt value="Channel B" id="ChannelB"/>
    </Type>
    <Type name="tAnalog">
      <Prompt value="Analog 1" id="Analog1"/>
      <Prompt value="Analog 2 (if supported)" id="Analog2"/>
    </Type>
    <Type name="tDescription" prompt="Comment" units=""/>
    <Type name="tWavelength" prompt="Wavelength" units="nm"/>
    <Type name="tDataRate" prompt="Sampling Rate" units="points/sec"/>
    <Type name="tDataMode" prompt="Data Mode" units="">
      <Enum value="Absorbance" id="SingleMode_1A"/>
      <Enum value="Absorbance -MBF" id="SingleMode_14A"/>
      <!-- Note: removed solely for compatibility with Masslynx...   <Enum value="Both" id="SingleMode_16A"/> -->
      <Enum value="Absorbance A" id="DualModeA_1B"/>
      <Enum value="Absorbance -MBF A" id="DualModeA_14B"/>
      <!-- Note: removed solely for compatibility with Masslynx...   <Enum value="Both A Absorbances" id="DualModeA_16B"/> -->
      <Enum value="Max Plot (A,B)" id="DualModeA_5B"/>
      <Enum value="Ratio A/B" id="DualModeA_6B"/>
      <Enum value="Difference A-B" id="DualModeA_8B"/>
      <Enum value="Absorbance B" id="DualModeB_2C"/>
      <Enum value="Absorbance -MBF B" id="DualModeB_15C"/>
      <!-- Note: removed solely for compatibility with Masslynx...   <Enum value="Both B Absorbances" id="DualModeB_17C"/> -->
      <Enum value="Max Plot (A,B)" id="DualModeB_5C"/>
      <Enum value="Ratio A/B" id="DualModeB_6C"/>
      <Enum value="Difference A-B" id="DualModeB_8C"/>
    </Type>
    <Type name="tDataStatus">
      <Enum value="Uninitialized" id="DataUninitialized_0"/>
      <Enum value="Initializing Data Status" id="DataInitializing_1"/>
      <Enum value="Calibrating" id="DataCalibrating_2"/>
      <Enum value="Single Wavelength" id="DataSingle_3"/>
      <Enum value="Dual Wavelength" id="DataDual_4"/>
      <Enum value="Acquiring Scan" id="DataScanning_5"/>
      <Enum value="Playing Scan" id="DataPlayingScan_6"/>
      <Enum value="Idle Data Status" id="DataIdle_7"/>
      <Enum value="Error Data Status" id="DataError_8"/>
    </Type>
    <Type name="tDataRate">
      <Enum value="1" id="SingleDataRate_1A"/>
      <Enum value="2" id="SingleDataRate_2A"/>
      <Enum value="5" id="SingleDataRate_5A"/>
      <Enum value="10" id="SingleDataRate_10A"/>
      <Enum value="20" id="SingleDataRate_20A"/>
      <Enum value="40" id="SingleDataRate_40A"/>
      <Enum value="80" id="SingleDataRate_80A"/>
      <Enum value="1" id="DualDataRate_1B"/>
      <Enum value="2" id="DualDataRate_2B"/>
    </Type>
    <Type name="tLampState">
      <Enum value="Off" id="LampOff_0"/>
      <Enum value="Lighting" id="LampLighting_1"/>
      <Enum value="Warmup" id="LampWarmup_2"/>
      <Enum value="On" id="LampOn_3"/>
      <Enum value="Error" id="LampError_4"/>
    </Type>
    <Type name="tFilterType" prompt="Noise Filter Type" units="">
      <Enum value="None" id="Filter_1"/>
      <Enum value="Hamming" id="Filter_2"/>
      <Enum value="RC" id="Filter_3"/>
    </Type>
    <Type name="tFilterDisable">
      <Enum value="No Filter" id="FilterDisable_0"/>
    </Type>
    <Type name="tTimeConstant" prompt="Time Constant" units="sec">
      <Enum value="No filter" id="FilterDisable"/>
    </Type>
    <Type name="tRatioAU" prompt="Ratio Minimum" units=""/>
    <Type name="tAutoZeroWavelength" prompt="Auto Zero On Wavelength Change" units="">
      <Enum value="Disable" id="Az_1"/>
      <Enum value="Offset to Zero" id="Az_2"/>
      <Enum value="Maintain Baseline" id="Az_3"/>
    </Type>
    <Type name="tAutoZeroInjectStart" prompt="Auto Zero On Inject Start" units=""/>
    <Type name="tAutoZeroEventOrKey" prompt="Auto Zero On Event or Console Input" units=""/>
    <!-- End Channel -->
    <!-- Begin Analog -->
    <Type name="tSensitivity" prompt="Sensitivity" units="AUFS"/>
    <Type name="tPolarity" prompt="Chart Polarity" units="">
      <Enum value="Positive (+)" id="NormalPolarity_1"/>
      <Enum value="Negative (-)" id="InversePolarity_0"/>
    </Type>
    <Type name="tAbsorbanceOffset" prompt="Absorbance Offset" units="AU"/>
    <Type name="tVoltageOffset" prompt="Voltage Offset" units="mV"/>
    <Type name="tRatio" units="AU">
      <Prompt value="Minimum Ratio" id="RatioMinimum"/>
      <Prompt value="Maximum Ratio" id="RatioMaximum"/>
    </Type>
    <Type name="tChartMarkEnable" prompt="Enable Chart Mark" units=""/>
    <!-- End Analog -->
    <Type name="tRunEvents" prompt="Run Events" units=""/>
    <!-- Begin Event Table -->
    <Type name="tEventTable" prompt="Event Table"/>
    <Type name="tEventTime" prompt="Time" units="min"/>
    <Type name="tEventEnum" prompt="Event" units="">
      <Enum value="Wavelength" id="EventWavelength_1A"/>
      <Enum value="Time Constant" id="EventTimeConstant_2A"/>
      <Enum value="Sensitivity" id="EventSensitivity_3A"/>
      <Enum value="Chart Mark" id="EventChartMark_4A"/>
      <Enum value="Chart Polarity" id="EventChartPolarity_5A"/>
      <Enum value="Auto Zero" id="EventAutoZero_6A"/>
      <Enum value="Lamp" id="EventLamp_7A"/>
      <Enum value="Switch 1" id="EventSwitch1_8A"/>
      <Enum value="Switch 2" id="EventSwitch2_9A"/>
      <Enum value="Threshold" id="EventThreshold_12A"/>
      <Enum value="Wavelength" id="EventWavelength_1B"/>
      <Enum value="Time Constant" id="EventTimeConstant_2B"/>
      <Enum value="Sensitivity" id="EventSensitivity_3B"/>
      <Enum value="Chart Mark" id="EventChartMark_4B"/>
      <Enum value="Chart Polarity" id="EventChartPolarity_5B"/>
      <Enum value="Auto Zero" id="EventAutoZero_6B"/>
      <Enum value="Lamp" id="EventLamp_7B"/>
      <Enum value="Event Out" id="EventSwitch1_8B"/>
      <Enum value="Switch 2" id="EventSwitch2_9B"/>
      <Enum value="Threshold" id="EventThreshold_12B"/>
    </Type>
    <Type name="tParameterEnum" prompt="Action" units="">
      <Enum value="On" id="SwitchParameterOn_1A"/>
      <Enum value="Off" id="SwitchParameterOff_2A"/>
      <Enum value="Pulse" id="SwitchParameterPulse_3A"/>
      <Enum value="Rect wave" id="SwitchParameterRectWave_4A"/>
      <Enum value="Positive (+)" id="PolarityParameterPositive_1B"/>
      <Enum value="Negative (-)" id="PolarityParameterNegative_0B"/>
      <Enum value="Off" id="LampParameterOff_0C"/>
      <Enum value="On" id="LampParameterOn_1C"/>
    </Type>
    <Type name="tEventChannelEnum" prompt="Channel" units="">
      <Enum value="Channel A" id="DataChannel_1A"/>
      <Enum value="Channel B" id="DataChannel_2A"/>
      <Enum value="Analog 1" id="DataChannel_1B"/>
      <Enum value="Analog 2" id="DataChannel_2B"/>
      <Enum value="Channel A" id="DataChannel_1C"/>
      <Enum value="Analog 1" id="DataChannel_1D"/>
      <Enum value="Analog Out" id="DataChannel_1E"/>
    </Type>
    <!-- End Event Table -->
    <!-- Begin Threshold -->
    <Type name="tThresholdEnable" prompt="Enable threshold event"/>
    <Type name="tThresholdLevel" prompt="Threshold" units="AU"/>
    <Type name="tThresholdEvent" prompt="Threshold event">
      <Enum value="Switch 1" id="ThresholdEvent_8"/>
      <Enum value="Switch 2" id="ThresholdEvent_9"/>
    </Type>
    <Type name="tThresholdAction" prompt="Threshold switch action">
      <Enum value="On" id="ThresholdAction_1"/>
      <Enum value="Off" id="ThresholdAction_2"/>
      <Enum value="Pulse" id="ThresholdAction_3"/>
      <Enum value="Rect wave" id="ThresholdAction_4"/>
    </Type>
    <!-- End Threshold -->
    <Type name="tPulseWidth" prompt="Pulse Width" units="sec"/>
    <Type name="tRectWavePeriod" prompt="Rect Wave Period" units="sec"/>
  </TypeCollection>
  <TypeCollection name="StatusDetail">
    <Type name="tFilterPosition">
      <Enum value="None" id="FilterPositionNone_0"/>
      <Enum value="Order" id="FilterPositionOrder_1"/>
      <Enum value="Erbium" id="FilterPositionErbium_2"/>
      <Enum value="Shutter" id="FilterPositionShutter_3"/>
      <Enum value="Auto" id="FilterPositionAuto_4"/>
    </Type>
    <Type name="tSystemState">
      <Enum value="Initializing" id="SystemStateInitializing_0"/>
      <Enum value="Idle" id="SystemStateIdle_1"/>
      <Enum value="Getting Ready" id="SystemStateGettingReady_2"/>
      <Enum value="Ready" id="SystemStateReady_3"/>
      <Enum value="Running" id="SystemStateRunning_4"/>
      <Enum value="Error" id="SystemStateError_5"/>
    </Type>
    <Type name="tLeakDetectorState">
      <Enum value="Leak Detected" id="LeakDetectorState_1"/>
      <Enum value="No Leak" id="LeakDetectorState_2"/>
      <Enum value="Not Found" id="LeakDetectorState_3"/>
      <Enum value="Not Supported" id="LeakDetectorState_4"/>
    </Type>
    <Type name="tLeakDetectorConfig">
      <Enum value="Disabled" id="LeakDetectorConfig_1"/>
      <Enum value="Enabled" id="LeakDetectorConfig_2"/>
    </Type>
    <Type name="tAlarmType">
      <Enum value="" id="Alarm_None_0"/>
      <Enum value="Grating initialization failure" id="Alarm_GratingHomeFail_1"/>
      <Enum value="Lamp lighting failure" id="Alarm_LampIgnition_2"/>
      <Enum value="Lamp external input conflict" id="Alarm_LampExternalInput_3"/>
      <Enum value="Lamp failure" id="Alarm_LampFail_4"/>
      <Enum value="Lamp energy low" id="Alarm_LampEnergyLow_5"/>
      <Enum value="Filter initialization failure" id="Alarm_OpticalFilterFail_6"/>
      <Enum value="Dark current" id="Alarm_DarkCurrent_7"/>
      <Enum value="Light level error" id="Alarm_AtoDError_8"/>
      <Enum value="System not calibrated, try to calibrate" id="Alarm_NotCalibrated_9"/>
      <Enum value="Calibration unsuccessful" id="Alarm_CalibrateFail_10"/>
      <Enum value="Calibration differs" id="Alarm_VerificationFail_11"/>
      <Enum value="Calibration not found" id="Alarm_CalibrateChecksum_12"/>
      <Enum value="Method not found" id="Alarm_MethodChecksum_13"/>
      <Enum value="Scan not found" id="Alarm_ScanChecksum_14"/>
      <Enum value="Configuration not found" id="Alarm_InstConfigChecksum_15"/>
      <Enum value="Communication failure" id="Alarm_TransducerComm_16"/>
      <Enum value="Peak not found" id="Alarm_PeakNotFound_17"/>
      <Enum value="Wavelengths span 370nm" id="Alarm_OrderFilter_18"/>
      <Enum value="Calibration successful" id="Alarm_CalComplete_19"/>
      <Enum value="System cannot respond" id="Alarm_BadSystem_20"/>
      <Enum value="Lamp data not found" id="Alarm_LampLifeChecksum_21"/>
      <Enum value="Peak not found" id="Alarm_656PeakNotFound_22"/>
      <Enum value="Lowered gain to avoid saturation" id="Alarm_AutoGainChange_23"/>
      <Enum value="No interrupt from preAmp board" id="Alarm_BadInterrupt_24"/>
      <Enum value="Mux ADC reset command failure" id="Alarm_MuxAdcReset_25"/>
      <Enum value="Mux ADC default register error" id="Alarm_MuxAdcInitialization_26"/>
      <Enum value="Mux ADC calibration command failure" id="Alarm_MuxAdcCalibration_27"/>
      <Enum value="Mux ADC input selection failure" id="Alarm_MuxAdcInputSelect_28"/>
      <Enum value="Remote command received while calibrating" id="Alarm_RemoteCommandInit_29"/>
      <Enum value="Leak sensor voltage too high or too low" id="Alarm_BadLeakDetSensor_30"/>
      <Enum value="Leak detected" id="Alarm_LeakDetected_31"/>
      <Enum value="Leak sensor not calibrated" id="Alarm_LeakDetNotCalibrated_32"/>
      <Enum value="Leak sensor power too high or too low" id="Alarm_LeakDetectorFailed_33"/>
      <Enum value="Leak sensor still warming up, cannot calibrate" id="Alarm_LeakDetNotReady_34"/>
      <Enum value="Leak sensor not present" id="Alarm_LeakDetNotPresent_35"/>
      <Enum value="Leak sensor not enabled" id="Alarm_LeakDetNotEnabled_36"/>
      <Enum value="Serial number was modified" id="Alarm_ModifiedSN_37"/>
      <Enum value="Lamp hours counter exceeded" id="Alarm_LampHoursExceeded_38"/>
      <Enum value="Ethernet cable was disconnected" id="Alarm_EthernetCableDisconnected_39"/>
      <Enum value="Ambient temperature sensor HW fault" id="Alarm_AmbientHardware_40"/>
      <Enum value="Lamp temperature sensor HW fault" id="Alarm_LampHsngHardware_41"/>
      <Enum value="Ambient temperature outside specified range" id="Alarm_AmbientRange_42"/>
      <Enum value="Leak sensor enabled" id="Alarm_LeakDetEnabled_43"/>
      <Enum value="Leak sensor disabled" id="Alarm_LeakDetDisabled_44"/>
      <Enum value="Leak sensor not supported" id="Alarm_LeakDetNotSupported_45"/>
      <Enum value="24 Volts fuse failed" id="Alarm_24VoltsFuseError_46"/>
      <Enum value="Vcc fuse failed" id="Alarm_VccFuseError_47"/>
      <Enum value="Flow cell resident memory device not connected" id="Alarm_FlowCellMemDeviceNotConnected_48"/>
      <Enum value="Lamp resident memory device not connected" id="Alarm_LampMemDeviceNotConnected_49"/>
      <Enum value="Lamp and flow cell resident memory devices not programmed" id="Alarm_MemoryDevicesNotProgrammed_50"/>
      <Enum value="Flow cell resident memory device not programmed" id="Alarm_FlowCellMemDeviceNotProgrammed_51"/>
      <Enum value="Data buffer overflow" id="Alarm_AlarmDataBufferOverflow_52"/>
      <Enum value="Lamp and Flow cell resident devices contain flow cell info" id="Alarm_AlarmBothMemDevicesContainFCInfo_53"/>
      <Enum value="Lamp and Flow cell resident devices contain lamp info" id="Alarm_AlarmBothMemDevicesContainLampInfo_54"/>
      <Enum value="Communication Failure" id="ICSAlarmCommFailure_3000"/>
      <Enum value="%s conflicts with the instrument LAN assigned to %s; please run the DHCP Configuration Wizard to choose an alternate address." id="ICSAlarmLANConflict_3002"/>
      <Enum value="Minimum UV firmware %s not found. Please upgrade." id="ICSAlarmMinimumFirmwareVersion_3003"/>
      <Enum value="Invalid system configuration" id="ICSAlarmInvalidSystem_3004"/>
    </Type>
    <Type name="tExtAlarm">
      <Enum value="" id="ExtAlarm_None_0"/>
      <Enum value="Missing/Bad Sensor" id="ExtAlarm_TextGratingHomeFail_1"/>
      <Enum value="Reference or Sample A/D" id="ExtAlarm_ReferenceOrSampleAToD_2"/>
      <Enum value="D2 656 nm. Flowcell Bubbles? Try Calibrate" id="ExtAlarm_FlowcellBubbles_3"/>
      <Enum value="Backlash too high. Flowcell Bubbles? Try Cal" id="ExtAlarm_BacklashTooHigh_4"/>
      <Enum value="Air in Cell? Try to Calibrate" id="ExtAlarm_AirInCell_5"/>
      <Enum value="\nErbium 257 nm. Flowcell Bubbles? Try Calibrate" id="ExtAlarm_Erbium257Bubbles_6"/>
      <Enum value="\nErbium 379 nm. Flowcell Bubbles? Try Calibrate" id="ExtAlarm_Erbium379Bubbles_7"/>
      <Enum value="\nErbium 521 nm. Flowcell Bubbles? Try Calibrate" id="ExtAlarm_Erbium521Bubbles_8"/>
      <Enum value="257 Peak out of range. Flowcell Bubbles? " id="ExtAlarm_PeakOutOfRange257_9"/>
      <Enum value="379 Peak out of range. Flowcell Bubbles? " id="ExtAlarm_PeakOutOfRange379_10"/>
      <Enum value="521 Peak out of range. Flowcell Bubbles? " id="ExtAlarm_PeakOutOfRange521_11"/>
      <Enum value="257 nm. Flowcell bubbles possible. Try Calibrate" id="ExtAlarm_Verify257Flowcell_12"/>
      <Enum value="379 nm. Flowcell bubbles possible. Try Calibrate" id="ExtAlarm_Verify379Flowcell_13"/>
      <Enum value="521 nm. Flowcell bubbles possible. Try Calibrate" id="ExtAlarm_Verify521Flowcell_14"/>
      <Enum value="Order Filter not in use for nm: " id="ExtAlarm_OrderFilterNanometer_15"/>
      <Enum value="Ref. Saturated. Cycle Power" id="ExtAlarm_RefSaturatedCycle_16"/>
      <Enum value="Ref. Light Level Increased" id="ExtAlarm_RefLevelIncreased_17"/>
      <Enum value="Sample Light Level Increased" id="ExtAlarm_SampleLevelIncreased_18"/>
      <Enum value="Lock. Cannot Continue" id="ExtAlarm_LockCannotContinue_19"/>
      <Enum value="Waiting for Data in Dual" id="ExtAlarm_WaitingInDual_20"/>
      <Enum value="Average Samples" id="ExtAlarm_AverageSamplesText_21"/>
      <Enum value="Max nm deviation since last calibration: " id="ExtAlarm_MaxDeviationSinceLast_22"/>
      <Enum value="Defaults Set" id="ExtAlarm_DefaultsSetText_23"/>
      <Enum value="TimeOut" id="ExtAlarm_TimeoutText_24"/>
      <Enum value="LifeTime Defaults Set" id="ExtAlarm_LifetimeDefaults_25"/>
      <Enum value="History Defaults Set" id="ExtAlarm_HistoryDefaults_26"/>
      <Enum value="No reference energy" id="ExtAlarm_NoReferenceEnergyText_27"/>
      <Enum value="No filters found" id="ExtAlarm_NoFiltersFound_28"/>
      <Enum value="Shutter position" id="ExtAlarm_ShutterPosition_29"/>
      <Enum value="Order filter position" id="ExtAlarm_OrderFilterPosition_30"/>
      <Enum value="Erbium position" id="ExtAlarm_ErbiumPosition_31"/>
      <Enum value="Reference Dark too high" id="ExtAlarm_ReferenceDarkTooHigh_32"/>
      <Enum value="Sample Dark too high" id="ExtAlarm_SampleDarkTooHigh_33"/>
      <Enum value="Unable to process set commands at this time" id="ExtAlarm_InitCalRemoteWarning_34"/>
      <Enum value="Detector must be on for at least 20 minutes" id="ExtAlarm_WarmUpTime_35"/>
      <Enum value="Cannot enable leak sensor" id="ExtAlarm_LeakDetectorEnable_36"/>
      <Enum value="Thermal controller disabled" id="ExtAlarm_ThermalControllerDisabled_37"/>
      <Enum value="Ambient range for detector is 4 to 40 deg C" id="ExtAlarm_AmbientTemperatureRange_38"/>
    </Type>
    <Type name="tFunction">
      <Enum value="" id="Fid_NoFunction_0"/>
      <Enum value="Diagnostic" id="Fid_Diagnostic_1"/>
      <Enum value="" id="Fid_None_1000"/>
      <Enum value="LC Data Acquisition" id="Fid_LcChromatogram_1001"/>
      <Enum value="Running Interactive Control" id="Fid_InteractiveControl_1002"/>
      <Enum value="Initializing Function" id="Fid_Initialize_1003"/>
      <Enum value="Calibrating" id="Fid_Calibrate_1004"/>
      <Enum value="Zero Scan" id="Fid_ZeroScan_1005"/>
      <Enum value="Sample Scan" id="Fid_SampleScan_1006"/>
      <Enum value="Drift Test" id="Fid_DriftTest_1007"/>
      <Enum value="Noise Test" id="Fid_NoiseTest_1008"/>
      <Enum value="Calibrating Leak Sensor" id="Fid_CalLeakDet_1009"/>
    </Type>
    <Type name="tFunctionTextID">
      <Enum value="" id="FidState_NoiseNull_0"/>
      <Enum value="No Function Text" id="FidState_NoiseNull_140_0"/>
      <Enum value="Setting filter parameters" id="FidState_NoiseSetFilter_1"/>
      <Enum value="Autozeroing" id="FidState_NoiseAutoZero_2"/>
      <Enum value="Collecting test data" id="FidState_NoiseTakeData_3"/>
      <Enum value="Calculating statistics" id="FidState_NoiseCalcStats_4"/>
      <Enum value="Finished Noise test" id="FidState_NoiseDone_5"/>
      <Enum value="" id="FidState_NoiseReserved1_6"/>
      <Enum value="" id="FidState_NoiseReserved2_7"/>
      <Enum value="" id="FidState_CalNull_8"/>
      <Enum value="Initializing transducers" id="FidState_CalInitTransducers_9"/>
      <Enum value="Initializing acquisition manager" id="FidState_CalInitAcqman_10"/>
      <Enum value="Lighting lamp" id="FidState_CalStartLamp_11"/>
      <Enum value="Lamp warming" id="FidState_CalLampWarmup_12"/>
      <Enum value="Performing autozero" id="FidState_CalAutoZero_13"/>
      <Enum value="Checking grating calibration" id="FidState_CalCheckCal_14"/>
      <Enum value="Initializing grating" id="FidState_CalInitGrating_15"/>
      <Enum value="Homing optical filter" id="FidState_CalInitOpticalFilter_16"/>
      <Enum value="Searching for 656nm" id="FidState_CalFind656Peak_17"/>
      <Enum value="Optimizing system performance" id="FidState_CalAdjustSysGain_18"/>
      <Enum value="Removing system offsets" id="FidState_CalRemoveSysOffset_19"/>
      <Enum value="Restoring last setup" id="FidState_CalRestoringParameters_20"/>
      <Enum value="Completing initialization" id="FidState_CalDone_21"/>
      <Enum value="" id="FidState_CalReserved1_22"/>
      <Enum value="" id="FidState_CalReserved2_23"/>
      <Enum value="" id="FidState_ScanNull_24"/>
      <Enum value="Setting Up" id="FidState_ScanSettingUp_25"/>
      <Enum value="Scanning" id="FidState_ScanScanning_26"/>
      <Enum value="Playing" id="FidState_ScanPlaying_27"/>
      <Enum value="Restoring Mode" id="FidState_ScanCleaningUp_28"/>
      <Enum value="Finished Scanning" id="FidState_ScanDone_29"/>
      <Enum value="" id="FidState_ScanReserved1_30"/>
      <Enum value="" id="FidState_ScanReserved2_31"/>
      <Enum value="" id="FidState_LeakDetNull_32"/>
      <Enum value="Calibrating Leak Sensor" id="FidState_LeakDetCal_33"/>
      <Enum value="Done" id="FidState_LeakDetDone_34"/>
      <Enum value="Delaying-MBF ({0:F2}#0# min)" id="FidState_DelayingMBF_35"/>
    </Type>
  </TypeCollection>
</ICSResources>