<?xml version="1.0" encoding="UTF-8"?>
<SigmaProbe>
	<!--********************************************************************************************************************-->
	<!-- SigmaProbe 5.0 - SigmaProbe service configuration file.                                                            -->
	<!-- Copyright 2001-2006 SigmaQuest Inc.                                                                                -->
	<!--====================================================================================================================-->
	<!-- This file is created and modified based on the user input during the SigmaProbe installation                       -->
	<!-- This file is accessed by both the SigmaProbe API DLL and SigmaProbe service                                        -->
	<!--====================================================================================================================-->
	<!-- The following section explains attributes used in this file:                                                       -->
	<!--                                                                                                                    -->
	<!-- queue-name                 - XML file generated by the API are named as <queue-name>_<GUID>.xml.                   -->
	<!-- queue-directory            - The Directory in which the XML files are stored.                                      -->
	<!-- interval                   - Defines queue lookup frequency in seconds by the SigmaProbe service.                  -->
	<!-- hostname                   - Defines address and port number of a SigmaConnect server.                             -->
	<!-- service-url                - Defines URL of UnitReport import web service.                                         --> 
	<!-- deliver-invalid-reports    - Set to true to deliver invalid XML files to SigmaConnect server.                      -->
	<!--                              Invalid XML files are XML files which are not well-formed and can be created as a     -->
	<!--                              result of a bug in the code, manual alternation of XML report, or machine crash.      -->
	<!-- save-reports               - Set to true to save a copy of XML UnitReport to a backup location. The backup         -->
	<!--                              location is determined by value of save-reports-directory attribute.                  -->
	<!-- save-reports-directory     - Set path of a backup directory.                                                       -->
	<!-- mode                       - SigmaProbe can operate in two modes (D - Debug, P - Production).                      -->
	<!--                              Set the value of this attribute to "D" if you want all files being created to be      -->
	<!--                              tagged with debug flag (default D).                                                   -->
	<!-- validateFiles              - Set to true to instruct SigmaProbe service to validate XML files (in addition to      -->
	<!--                              validation performed by SigmaConnect server. Enabling SigmaProbe service validation   -->
	<!--                              will slow delivery of XML files to SigmaConnect server.                               -->
	<!-- auto-create-operator       - Set to true to automatically register new operator under SigmaConnect server.         -->
	<!-- auto-create-test           - Set to true to automatically register new test under SigmaConnect server.             -->
	<!-- auto-create-product        - Set to true to automatically register new product under SigmaConnect server.          --> 
	<!-- auto-create-property       - Set to true to automatically register new property under SigmaConnect server.         --> 
	<!-- guid                       - Specifies station unique identifier (Global Unique Identifier). Each test station is  -->
	<!--                              uniquely identified by the GUID value, which must be defined under SigmaSure Setup.   -->
	<!--                              SigmaProbe API uses value of this attribute to "stamp" every XML created to indicate  -->
	<!--                              which test station generated report. SigmaConnect server will reject any XML report 	-->
	<!--				              created by a station with an unknown GUID.                                            -->
	<!--                              be otherwise rejected by SigmaConnect server.                                         -->
	<!-- max-file-size              - Specify size (in bytes) of a maximum XML file size to be delivered to SigmaConnect    -->
	<!--                              server by SigmaProbe service.                                                         -->
	<!-- xml-file-compressed        - Specifies if the XML files in the queue-directory are compressed. Default false       -->
	<!-- monitor-connect            - Specifies if the SigmaConnect needs to be monitored by the SigmaProbe. Default false  -->
	<!-- max-files-in-buffer        - Specifies the maximum number of files in the SENDBUFFER directory. Default 100        -->
	<!-- number-of-threads          - Specifies the number of threads per Queue. Default 2.                                 -->
	<!-- transmission-delay 	- Specifies the time delay in milli seconds after which a newly created file is         -->
	<!--                              transmitted. This delay ensures that any data in the buffer gets flushed before it is -->
	<!--                              picked up from transmission. Default value is 10000 (10 seconds). Value of 0 means    -->
	<!--                              that the file is eligible for transmission immediately. 	                        -->
	<!-- delete-duplicate-files    	- If SigmaProbe tries to import the same file more than once then delete it.         	-->	
	<!--********************************************************************************************************************-->	
	<!-- First queue definition -->
	<SigmaQueue 
		queue-name="SigmaQueue" 
		queue-directory="C:\Program Files\SigmaQuest\SigmaProbe\SigmaQueue\"
		hostname="sigmaprod.corp.waters.com"
		service-url="/sigma/services/UnitReport"
		interval="10"
		max-file-size="2048000"
		deliver-invalid-reports="false"
		save-reports="true"
		save-reports-directory="C:\Program Files\SigmaQuest\SigmaProbe\SigmaQueueBackup"
		mode="P"
		validateFiles="false"
		auto-create-operator="true"
		auto-create-test="true"
		auto-create-product="true"
		auto-create-property="true"	
		guid="E5DA88C1-5039-4F4D-BD1E-FD7255BAEE17"
		xml-file-compressed="false"
		monitor-connect="true"
		max-files-in-buffer="100"
		number-of-threads="2"
		transmission-delay="0"
		delete-duplicate-files="true"
	/>
</SigmaProbe>